Aquaduct at Tawa Canal DivisionAquaduct

 Problem:
MP WRD had undertaken strengthening of the piers of Ganjal Aqueduct at Tawa left bank Main canal. It was required considering durability aspect of the aquaduct.

Solution:
The job involved Polymer plaster for section built-up, excavation to expose piers, application of carbon fiber wraps in two layers, plastering and painting.