Earthquake damaged
Earthquake Damages, Rehabilitation & Retrofitting: IFFCO Kandla
Problem:
- Failure of RCC structure because of Bhuj earthquake in 2001
- Acid spillage is often encountered
- Plant is near sea coast, steel reinforcement cannot be used in such aggressive environment
- Plant had to be commissioned within 30 days as loss of production was not insured
Solution:
- Preliminary repairs with micro-concrete and polymer modified mortar
- Wrapping of failed members and beam column connection with glass fiber reinforcement
- Plant was re-started within 30 days
- Observations over last 11 years do not show any sign of decay indicating high durability of repair system in very aggressive environment
Strengthening Masonry Walls, South Mumbai
Strengthening Masonry Walls, South Mumbai
Problem:
- 90 years old brick masonry building
- Floor to floor height 20 feet
- Client created additional floor of 10 feet each in between
- Additional floor load caused failure of brick columns
Solution:
- Support was provided immediately prior to carrying out the repairs.
- All the damaged brick columns were wrapped with bidirectional glass fiber wraps
- After wrapping brick piers were grouted with polymers cement slurry
- The job was completed in 4 days
- Showing excellent performance for last 7 years
Seismic Retrofitting of Hospital Building, South Mumbai
Seismic Retrofitting of Hospital Building, South Mumbai
Problem:
- G+3- 90 years old timber masonry structure in South Mumbai
- Timber structure frame joints were badly affected by termite attack
- This has affected stability of frame
- Residents were against providing steel frame supports, which would have affected their movement in home giving feeling of unsafe structure
Solution:
- Timber joist were cleaned and anti-termite treatment was carried out
- Stiffening of beam column joint was carried out by using glass fiber wraps
- Small steel cages were introduced and gaps were filled with micro concrete followed by wrapping
Salient Features:
- Total 200 nos. of joints were treated without relocating occupants of building
- Total 1200 Kgs of FRP materials were used as against 90 T of steel initially proposed
- Entire work was completed in 6 months period
- Retrofit system performing in satisfactory manner for last 7 years